paralleling all-in-one marine GENSYS 2.0 CORE MARINE Core unit for all-in-one genset control and paralleling unit with integrated PLC : PMS •Rear mounted control and paralleling module •To be used with remote display module :, •I/O flexibility •Isolated communication ports: RS485, 2 CAN bus, •Ethernet + SD card reader •Fully compatible with all speed governors and AVRs •Engineering services for specific applications •Marine sequencies •Marine approval : DNV The GENSYS 2.0 CORE MARINE is an easy-to-use rear-mounted, control and paralleling module which can synchronize up to 32 generators. PROGRAMMING BY EQUATIONS GENSYS 2.0 CORE MARINE is configured with CRE Config software or via its embedded Web site. The number of inputs/outputs that can be added is one of the most important on the market. Extension modules (DIN rail mounting) can be added on the CAN bus. This extends a large number and a large diversity of inputs/outputs up to 128 digital inputs, 64 digital outputs, 44 analog inputs, 32 analog outputs and CANopen standard module. The GENSYS 2.0 CORE MARINE module is a real PLC unit where equations and sequences can be programmed directly by the user with a Easy PLC software (cf p 66) or a simple text editor software. INPUTS / OUTPUTS EXTENSION MINIMUM OPTIONS The GENSYS 2.0 CORE MARINE is offered full features with a minimum of options to fit all types of application without expensive add-on packages. For specific needs, the following options are available: • Phase shift compensation (ie: Dyn11) INTER-UNIT ISOLATED CAN BUS The GENSYS 2.0 CORE MARINE features an isolated CANbus dedicated to inter-module communication (dead busbar management, static paralleling, kW and kVAR load sharing...). CANbus technology provides high reliability communication while maintaining low wiring cost and complexity. www.cretechnology.com FEATURES CHARACTERISTICS Control and management • Manual and automatic engine control. • Automatic start/stop control depending on load demand. • Dead busbar management. • Isochronous or droop kW load sharing control (via CAN bus serial port, up to 32 generators) • Constant voltage (or droop) kVAR load sharing control (via CAN bus, up to 32 generators) • Power factor control when paralleling with mains. • kW control (base load or peak shaving) when paralleling with mains. Current, voltage and frequency • DC voltage power supply input: 8 to 40VDC, 600mA at 12VDC and 300mA at 24VDC. • AC voltage inputs: 100 to 480Vac, 100mA max. Neutral terminal does not need to be connected. • AC current inputs: 0 to 5A, 1VA. Each phase is isolated from the others. • AC current overload: 15A during 10s. • Frequency measurement: 45 to 70 Hz – 15VAC minimum between phase and neutral. • Voltage control signal: the voltage control (AVR) is made either by a +/-5VDC output with adjustable span and offset or by digital outputs +/- pulses. Protections • Generator electrical protections: <F, >F, <U, >U, >I, >In, >P, <P, <-P, >Q, <Q, <-Q • Mains electrical protections (option) : <F, >F, <U, >U, >P, <P, <-P, >Q, <Q, <-Q, phase shit, df/dt. • Phase sequence protection, phase shift compensation. Synchronization • Manual and automatic frequency and phase synchronization (differential frequency meter + synchroscope available on screen). • Manual and automatic voltage synchronization (differential voltmeter available on screen). Alarms and events • The last 50 alarms and last 50 shutdowns are recorded on non volatile memory. • Data logging. Other • “Watchdog” digital output for microprocessor life signal. Environment • Operating temperature: -20 to +70°C • Storage temperature: -30 to +80°C • Humidity: 5 to 95%. Tropic-proof circuits for normal operation in humid conditions. • IP20 Inputs, outputs • Emergency stop input: normally closed 24V. • Relay outputs (crank and fuel): 5A. The 24V is provided through the emergency push button. • Relay outputs (breakers): 5A, 230VAC max. NO + NC available. • Transistor outputs: 350mA, overcurrent protected. • Analog inputs (oil pressure and water temp): 0 to 400 Ω. Calibration is configurable. • Analog inputs (spare 1 and spare 2): 0 to 10KΩ. • Calibration for speed and frequency control is made either by a +/-10VDC output with adjustable span and offset or by speed+/speed- contacts. • Magnetic pick up input: 100 to 10.000Hz, 2VAC minimum. • PWM output for CAT and Perkins engines Ports • Isolated communication ports are available: ͳͳ RS485 for Modbus RTU (read and write)/ male Sub-D 9 pins 120 Ω resistors selected by micro-switch. ͳͳ CAN bus for inter-GENSYS/ Master 2.0 connection: male Sub-D 9 pins 120 Ω resistors selected by micro-switch ͳͳ CAN bus dedicated to options J1939, I/O extensions: male Sub-D 9 pins 120 Ω resistors selected by micro-switch ͳͳ Ethernet: PC communication/ GENSYS 2.0 CORE and RDM 2.0 connection/ Modbus TCP ͳͳ SD card reader Size and weigh • Size: 248x197x57mm (9.76x7.76x2.24in) • Panel cut out: 177x228mm (6.97x8.98in) • Weight: 1kg (2.2lb) Certifications • European Union Directives: EN 50081-2, EN 50082-2, 73/23EEC PART NUMBER A53Z1 SOFTWARE CRE Config / Easy PLC www.cretechnology.com 59 From speed governor 4 mm2 wire -Alim - To speed governor F8 F9 F6 F7 F1 F2 F3 + +Alim www.cretechnology.com C3 GENSYS 2.0 C4 C5 E2 F5 F8 F9 F8 G2 G3 G1 G5 G6 G4 F9 E3 L6 L5 L4 L3 L2 L1 B5 Bus / Mains I1 + Spare input J6 Bus / Mains I2 Spare input J7Bus / Mains I2 + Spare input J8 Bus / Mains I3 Spare input J9 Bus / Mains I3 + Spare input J10 Bus / Mains L1 F6 1 - NC 2 - NC 3 - 0V 4 - 0V 5-B F6 6 - A F7 7 - NC 8 - NC 9 - 0V DB9 male RS 485 F7 F1 F1 F2 1 - NC 2 - CANL 3 - 0V 4 - NC 5 - 0V F2 6 - 0V F3 7 - CANH 8 - NC 9 - NC DB9 male CAN 1 F3 F4 a REV. J11 1 - NC 2 - CANL 3 - 0V 4 - NC 5 - 0V G2 6 - 0V 7 - CANH 8 - NC 9 - NC DB9 male CAN 2 DESCRIPT GENSYS 2.0 CORE c b DATE LB J14 J15 G3 USB Type B G1 N° DESSIN FEUILLE Spare input J14 Spare input J15 R=120 ohms COM 6 Memory G5 G6slot RJ45 J4 J5 J6 J7 J8 Spare J5 /Water temp Spare input J6 Spare input J7 Spare input J8 1 - NC 2 - NC 3 - 0V 4 - 0V 5-B 6-A 7 - NC 8 - NC 9 - 0V DB9 male RS 485 1 - NC 2 - CANL 3 - 0V 4 - NC 5 - 0V 6 - 0V 7 - CANH 8 - NC 9 - NC DB9 male CAN 1 Wiring example : 1 genset to mains application Wiring Gensys 2.0 A53Z0 J9 J10 REV. a 1 - NC 2 - CANL 3 - 0V 4 - NC 5 - 0V 6 - 0V 7 - CANH 8 - NC 9 - NC DB9 male CAN 2 If chassis not connected to 0V DESCRIPT J12 J13 J14 J15 Spare input J13 Spare input J14 Spare input J15 J11 Spare input J12 Spare input J11 Spare input examples: - +/- speed inputs - Low temp warning - Low water level - Low fuel warning - Charger fault - Air damper shut - Exter electrical fault - ... L3 Spare input J9 J3 Spare J4 /Oil press L2 Spare input J10 J2 Gen Breaker IN J1 Remote start/stop Mains breaker IN J13 Spare input J13 J12 Parallel - J10 B7 Parallel + J9 B6 F Shield J8 +/- 20mA + Not connected when several generators F Bus / Mains L2 Mains F Spare input J12 Bus / Mains L3 S1 Spare input J11 S2 +/- 20mA - J7 Shield J6 Engine meas. 2 - J5 Engine meas. 2 + J4 Spare Engine meas. 1 - J5 /Water temp J3 L1 c b DATE LB d PAR A53Z0 A 2001 C 1 DE 1 REV CABLE A53W1 ASSOCIATED PRODUCTS GENSYS 2.0 Complementary: RDM 2.0 COM 4 Isolated ETHERNET J2 P1 COM 3 Isolated USB to PC CRE use only J1 S1 P2 COM 2 Isolated CAN 2 J1939 +Alim E1 P1 COM 1 IsolatedCAN1 INTER-GENSYS + MASTER 2.0 B7 Spare input examples: - +/- speed inputs - Low temp warning - Low water level - Low fuel warning - Charger fault - Air damper shut - Exter electrical fault - ... - Alim COM 5 Isolated RS485 / MODBUS RTU B6 E6 Engine meas. + 100 - 500V Water temp meas + J4 /Oil press Bus / Mains I1 Spare F Mains Common Remote start/stop Water temp meas. - S2 COM 4 Isolated ETHERNET B5 E5 Oil pressure meas. + Mains Gen Breaker INClose Breaker L3 S1 P2 Parallel lines to GCR or WOODWARD analog load sharing L1 E4 Gen Common L2 P1 S2 COM 3 Isolated USB to PC +/- 20mA or only +/- 10V CRE use D1 Mains Oil pressure meas.Mains breaker INOpen Breaker L1 P2 COM 2 Isolated CAN 2 J1939 F4 S2 Mains power by external transducer F3 F - Alim COM 1 IsolatedCAN1 INTER-GENSYS + MASTER 2.0 F2 Parallel - F1 Parallel + F Shield S1 S2 Gen Close Breaker D2 Gen I1- P1 Output 5 D3 Gen I2- S2 P2 S1 Gen Open Breaker D4 Gen I1+ P1 Shield F7 C2 L2 Bus / Mains L3 D5 Gen I2+ S1 P2 Output 4 L3 Bus / Mains L2 L4 Bus / Mains L1 S2 Bus / Mains I3 - 1-5A S1 P2 Bus / Mains I3 + D6 Gen 3S2 +/- 20mA + F6 C1 S1 +/- 20mA - L5 N Output 3 B1 Gen N P1 Shield Engine meas. 2 + B4 Gen I3+ F Bus / Mains I2 - B3 Gen L3 S2 Bus / Mains I2 + L6 Bus / Mains I1 - F Output 2 Engine meas. 2 - F9 Engine meas. + A2 E3 P1 P2 S1 P2 COM 5 Isolated RS485 / MODBUS RTU F8 B2 Bus / Mains I1 + 100 - 480 V P2 P1 P1 Parallel lines to GCR or WOODWARD (Barber Colman) analog load sharing F5 E2 L3 SPARE A1 L2 SPARE C5 E1 L1 +/- 20mA or +/- 10V A3 +Alim E6 Engine meas. 1 - Output 1 E5 Mains power by external transducer F AVR Gen L2 F Water temp meas + Not connected when several generators Gen L1 H2 H4 H3 Mains Common Analog S2 Speed controller Water temp meas. - E4 - + OR - Alim SPARE C4 F AVR out + AVR out Shield 1 G SPARE K2 D1 - Alim Crank Gen Common relay out output 6 Mains Open Breaker Oil pressure meas. Fuel Oil pressure meas.relay + out output 7 Mains Close Breaker Load SPARE K3 D2 Shield PWM P2 ECU S2 FUEL CRANK C2 External Tank C3 Capacitor (optional) Shield analog P2 S1 Output 5 Pwm output Speed ref P1 SPARE K1 D3 Gen I1- EmergencyGen Open Breaker stop Gen Close Breaker G9 G11 G10 K4 Speed out+ G7 Gen I2- Power supply + G8 Gen I1+ Pickup input P1 Output 4 Pickup + S2 Power supply - D4 Gen I2+ 1-5A S1 Power Tank D5 Gen 3P2 S1 SPARE Chassis isolated from power supply Output 3 D6 Gen N F Pickup - B1 Gen I3+ P1 SPARE C1 SPARE B4 Gen L3 N Output 2 Output 1 L3 Spare output examples: - +/- speed to speed governor - Engine preglow - Visual / Audio alarm - Generator breaker trip - Lubrification pump - Reverse power - ... SPARE paralleling all-in-one GENSYS 2.0 CORE MARINE Manual start Unit Load Mains - Alim - Alim 100 - 500V R=120 ohms USB Type B COM 6 Memory slot RJ45 G4 If chassis connected to 0V F4 If chassis connected to 0V F4 If chassis not connected to 0V Wiring example : 1 genset to mains application Wiring Gensys 2.0 CORE A53Z1 d PAR N° DESSIN FEUILLE A53Z0 A 2001 C 1 DE 1 REV