Download A-V Impulse™
Document related concepts
no text concepts found
Transcript
16.2 Specifications Guidance and manufacturerâs declaration - electromagnetic emissions All values stated are nominal. Height: Depth: Width: Weight: The A-V Impulse 6000 Series Controller is intended for use in the electromagnetic environment specified below. The customer or the user of the A-V Impulse 6000 Series Controller should assure that it is used in such an environment. 16.5 cm overall 18.6 cm 32 cm 3.57 kg Electrical Supply: 120V 0.3A 60Hz Fuses: T1AH 250V x 20 mm (Antisurge) Standards: EN/IEC 60601-1, EN/IEC 60601-1-2, UL 60601-1, CAN/CSA C22.2 No. 601.1-M90, FCC Part 15 Class 1 Type B device Output Impulse Pressure: 60 - 200 mmHg Impulse Duration: 1 second / 3 second (3 second factory set default) Impulse Interval: 20 - 50 seconds (20 seconds factory set default) Operating conditions: Temperature 0°C - +45°C Transportation and storage conditions: Temperature -40°C to +70°C Relative humidity: 10%-95% condensing Atmospheric pressure: 500mbar-1060mbar Emissions test Compliance Electromagnetic environment â guidance RF emissions CISPR 11 Group 1 The A-V Impulse 6000 Series Controller uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions CISPR 11 Class B The A-V Impulse 6000 Series Controller is suitable for use in all establishments, including domestic establishments and those directly connected to the public lowvoltage power supply network that supplies buildings used for domestic purposes. Harmonic emissions IEC 61000-3-2 Class A Voltage fluctuations/ flicker emissions IEC 61000-3-3 Complies Guidance and manufacturerâs declaration â electromagnetic immunity The A-V Impulse 6000 Series Controller is intended for use in the electromagnet environment specified below. The customer or the user of the A-V Impulse 6000 Series Controller should assure that it is used in such an environment. Immunity test IEC 60601 Test level Compliance level Electromagnetic environment - guidance Electrostatic discharge (ESD) IEC 61000-4-2 ±6 kV contact ±8 kV air ±6 kV contact ±8 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Electrical fast transient/ burst IEC 61000-4-4 ±2 kV for power supply lines ±1 kV for input/output lines ±2 kV for power supply lines ±1 kV for input/output lines Mains power quality should be that of a typical commercial or hospital environment. Surge IEC 61000-4-5 ±1 kV differential mode ±2 kV common mode ±1 kV differential mode ±2 kV common mode Mains power quality should be that of a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 <5 % UT (>95 % dip in UT) for 0.5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles <5 % UT (>95 % dip in UT) for 5 sec <5 % UT (>95 % dip in UT) for 0.5 cycle 40 % UT (60 % dip in UT) for 5 cycles 70 % UT (30 % dip in UT) for 25 cycles <5 % UT (>95 % dip in UT) for 5 sec Mains power quality should be that of a typical commercial or hospital environment. If the user of the A-V Impulse 6000 Series Controller requires continued operation during power mains interruptions, it is recommended that the A-V Impulse 6000 Series Controller be powered from an uninterruptible power supply or a battery. Power frequency (50/60 Hz) magnetic field IEC 61000-4-8 3 A/m 3 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. 16.3 Impulse Pressure Conversion Table mmHg/KPa mmHG KPa mmHG KPa mmHG KPa 60 70 80 90 100 8.0 9.3 10.7 12.0 13.3 110 120 130 140 150 14.7 16.0 17.3 18.7 20.0 160 170 180 190 200 21.3 22.7 24.0 25.3 26.7 17. Guidance and Manufacturerâs Declaration - Electromagnetic Emission Warning: Medical electrical equipment needs special precautions regarding EMC and needs to be installed according to the EMC information provided. Careful consideration of this information is essential when stacking or collocating equipment and when routing cables and accessories. NOTE: UT is the a.c. mains voltage prior to application of the test level. Warning: RF mobile communications equipment can effect medical electrical equipment. EN-14 A-V Impulse System A-V Impulse System EN-15